[2023年01月] ベストな問題集を使おう Cisco and NetApp FlexPod NS0-176 専門試験問題 [Q31-Q52]

Share

[2023年01月] ベストな問題集を使おうCisco and NetApp FlexPod NS0-176専門試験問題

100%の合格率を試そう!更新されたのはNS0-176試験問題 [2023]

質問 31
When creating local user, which two are valid user names? (Choose two)

  • A. 1greatuser
  • B. best_user
  • C. daemon
  • D. somebody
  • E. 0
  • F. root

正解: B,D

 

質問 32
You have a NetApp clustered Data ONTAP storage system and vSphere 6 cluster. You discover that VMware VAAI for NFS is not showing as enabled on one of the five ESXi hosts in your vSphere cluster.
In this scenario, what must you do to enable VAAI for NFS on that ESXi host?

  • A. Set the DataMover. HardwareAcceleratedInit advanced setting to 0 on the ESXi host.
  • B. Install the NetApp NFS Plug-in for VMware VAAI on the ESXi host.
  • C. Enable VMware vStorage for NFS on the NetApp SVM.
  • D. Enable NFSv3 on the storage system.

正解: D

 

質問 33
Exhibit:

You just configured a new Storage Virtual Machine named SVM1 on your NetApp cluster to serve up NFS datastores to an ESX cluster.
Your VMware administrator tells you that the ESX servers are unable to access the datastore that you created on node flexpod1-san01-01. The IP address of one of the ESX servers is 10.33.128.100.
Referring to the exhibit, which command would you use to troubleshoot this problem?

  • A. ~network ping -lif flexpod1-san01-01 mgmt1 -vserver flexpod1-san01 -destination 10.33.128.100~
  • B. ~network ping -lif nfs1 -vserver svm1 -destination 10.33.128.100~
  • C. ~network ping -node flexpod1-san01-01 -destination 10.33.128.100~
  • D. ~network ping -lif cluster mgmt -vserver flexpodl-san01 - destination 10.33.128.100~

正解: B

 

質問 34
Which service may be used to manage users and groups in a vSphere environment?

  • A. Domain Name System (DNS)
  • B. Microsoft Active Directory (AD)
  • C. Network Time Protocol (NTP)
  • D. VMware vSphere Storage APIs for Array Integration (VAAI)

正解: B

 

質問 35
Where are log files located on a NetApp node?

  • A. /etc/mlog/
  • B. /mroot/etc/log/mlog/
  • C. /mroot/etc/crash/
  • D. /letc/log/crash
  • E. /log/core/

正解: B

 

質問 36
A customer asks you to configure QoS on a Cisco Nexus 7000 Series switch within a FlexPod solution.
Which three steps are required to accomplish this task? (Choose three.)

  • A. Attach policies to logical or physical interfaces and VLANs.
  • B. Define traffic classes.
  • C. Associate policies and actions with each traffic class.
  • D. Perform a shut/no shut on the affected interfaces.
  • E. Attach policies to logical or physical interfaces and VSANs.

正解: B,C,E

 

質問 37
Which two operating modes are available with the Nexus 9000 Series switches? (Choose two.)

  • A. Cisco ACI
  • B. Cisco IOS
  • C. Cisco IOS EX
  • D. Cisco NX-OS

正解: A,D

 

質問 38
Which endpoint's firmware can be directly upgraded (without the use of a Service Profile) using UCS Manager?

  • A. HBA
  • B. CIMC
  • C. RAID Controller
  • D. BIOS

正解: B,D

 

質問 39
An administrator is configuring a Flexpod Datacenter solution. The UCS service profiles will use FCoE connectivity to the NetApp cluster.
Which pool is needed to configure the vHBA templates?

  • A. WWPN pool
  • B. IQN pool
  • C. WWNN pool
  • D. MAC pool

正解: A

 

質問 40
A server administrator calls you complaining that an uplink on both UCS Fabric Interconnects went down. Each Fabric Interconnect has a vPC to the Nexus 500 switches.
After logging in to the switches, you notice that all vPC member ports on the secondary vPC peer switch are down. The vPC peer keepalive is still operational.
What is the problem in this scenario?

  • A. The vPC feature is disabled.
  • B. The vPC peer link is down.
  • C. A new VLAN was added to the UCS vPC member ports.
  • D. Both UCS Fabric Interconnects rebooted.

正解: B

 

質問 41
Your UCS environment has recently been upgraded to include UCS B-Series Servers, UCS C-Series Servers, a UCS mini, and a fourth UCS domain. With these new changes, you need a management tool to help you manage the entire environment from a single location.
In this scenario, which tool would you use?

  • A. UCS Central
  • B. UCS Director
  • C. Cisco Smart Advisor
  • D. UCS Manager

正解: A

 

質問 42
Which sends support summary information to NetApp through HTTPS?

  • A. AutoSupport
  • B. FlexSupport
  • C. TechSupport
  • D. SnapSupport

正解: A

 

質問 43
A customer uses Cisco Intersight and now wants to monitor their NetApp storage system with Intersight.
In this scenario, which three actions must be completed to accomplish this task? (Choose three.)

  • A. Activate the API Gateway in Active IQ Unified Manager.
  • B. Deploy Active IQ Unified Manager.
  • C. Get an Intersight Essentials tier license.
  • D. Get an Intersight Advantage tier license.
  • E. Activate the API Gateway in ONTAP System Manager.

正解: A,B,D

 

質問 44
Which two are two possible features of the 'Call Home' feature in UCS Manager?

  • A. Generates a syslog event
  • B. Allows UCS to proactively pull down new software updates from Cisco
  • C. Generates emails to predefined email addresses when a problem is detected
  • D. Generates a text message to configured cell phone numbers
  • E. Ability to proactively open a case with the Cisco TAC with the 'Smart Call Home' feature

正解: C,E

 

質問 45
In which two locations is the VSAN ID configured in a FlexPod solution? (Choose two.)

  • A. UCS Manager
  • B. hypervisor adapter
  • C. Nexus switches
  • D. Storage Virtual Machine

正解: A,C

 

質問 46
Exhibit:

Which hardware component is shown in the exhibit?

  • A. IOM
  • B. VIC
  • C. FI
  • D. FEX

正解: B

 

質問 47
When trying to configure a Virtual Port Channel (vPC), what might be a cause of the following error when trying to create the vPC domain?
Nexus-5548-B(config)# vpc domain 10
^% Invalid command at '^' marker.Nexus-5548-B(config)#

  • A. Have not yet turned on the vpc feature using the 'feature vpc' command
  • B. vPC domain cannot be configured at the global prompt
  • C. The vPC links have to be configured before the vPC domain can be added
  • D. The vPC domain has already been configured

正解: A

 

質問 48
A Cisco UCS system is operating in FC End-Host Mode. The fabric Interconnects are uplinked into Nexus 5672UP switches using native FC. The service profiles are unable to boot from SAN using FC.
When executing the show flogi database command on the Nexus switches, only the Fabric Interconnect port WWNs are visible. No service profile WWNs are shown.
What caused this issue?

  • A. The Nexus switches do not have NPV enabled.
  • B. The Nexus switches do not have NPIV enabled.
  • C. The zoning on the Nexus switches is incorrect.
  • D. The Nexus must be configured for FCoE instead of native Fibre Channel.

正解: B

 

質問 49
Exhibit:

You have a FlexPod solution with vSphere ESXi. When you click the icons shown in the exhibit, you do not see any network connectivity details.
Which Cisco UCS policy type should you create to enable visibility of these details?

  • A. Link Protocol Policy
  • B. Network Control Policy
  • C. Link Profile Policy
  • D. LAN Connectivity Policy

正解: D

 

質問 50
Which feature allows Cisco Nexus 7000 Series switches to be virtualized at the device level?

  • A. VRF
  • B. VDC
  • C. PONG
  • D. VLAN

正解: B

 

質問 51
Which two features allow multiple fabric logins through a single port? (Choose two.)

  • A. NPIV
  • B. vPC
  • C. LLDP
  • D. NPV

正解: A,D

 

質問 52
......

NS0-176試験問題を今すぐ試そう!最新の[2023年最新] 正解回答付き:https://www.goshiken.com/NetworkAppliance/NS0-176-mondaishu.html