[2023年10月23日] 最新でリアルなCDCP-001試験問題集解答
あなたを簡単に合格させるCDCP-001試験問と正確なCertified Data Centre ProfessionalのPDF問題
GAQMのCDCP-001試験は、電源と冷却要件、災害復旧計画、仮想化技術など、データセンター管理に関連する広範なトピックをカバーしています。この試験は、難易度が高く、個人はデータセンターの設計とメンテナンスに深い理解を持っている必要があります。この試験は100の多肢選択問題で構成され、3時間以内に完了する必要があります。この試験に合格するには、70%以上の最低スコアが必要です。
質問 # 22
Which one of the following does a Physical Infrastructure consists of in a Data Centre?
- A. Server
- B. Switch
- C. Hub
- D. Rack
正解:D
質問 # 23
Which one of the following is a factor that can affect Availability and Reliability?
- A. Attenuation
- B. Radio Active Waves
- C. Inadequate Cooling
- D. Employee Salaries
正解:C
質問 # 24
Which one of the following is a device that uses circulating chilled water to remove heat?
- A. Computer Room Air Suspension Unit (CRAS)
- B. Computer Room Air System Unit (CRAS)
- C. Computer Room Air Handling Unit (CRAH)
- D. Computer Room Air Suppression Unit (CRAS)
正解:C
質問 # 25
Cost of Downtime can be classified as .
- A. Classified and Declassified
- B. Mean and Median
- C. Direct and Indirect
- D. Up and Down
正解:C
質問 # 26
The three elements of the fire triangle are , and . (Choose three.)
- A. Oxygen
- B. Fuel
- C. Earth
- D. Water
- E. Heat
正解:A、B、E
質問 # 27
True or False: The time taken to diagnose the problem can be considered as Mean Time to Recover/Repair (MTTR).
- A. True
- B. False
正解:B
質問 # 28
Measuring "Business Values" begins first with __________.
- A. Topology
- B. Network
- C. Physical Infrastructure
- D. Budget
正解:D
質問 # 29
True or False: The most effective method of fire protection is fire prevention.
- A. True
- B. False
正解:A
質問 # 30
Which one of the following is a Natural Disaster?
- A. Human Error
- B. Hurricanes
- C. Blackouts
- D. Grid Failure
正解:B
質問 # 31
Which type of Humidifier is composed of water-filled canister containing electrodes?
- A. Infrared Humidifiers
- B. Steam Canister Humidifier
- C. Water Canister Humidifier
- D. Ultrasonic Humidifier
正解:B
質問 # 32
Which type of Humidifier rapidly vibrates waster to create a fog or mist?
- A. Ultrasonic Humidifier
- B. Infrared Humidifier
- C. Steam Canister Humidifier
- D. Water Canister Humidifier
正解:A
質問 # 33
Which one of the following is an Objective of Data Center Fire Protection?
- A. Representation
- B. Information
- C. Suppression
- D. Depression
正解:C
質問 # 34
How many monitoring points should be used in Temperature Measurement?
- A. 0
- B. 1
- C. 2
- D. 3
正解:A
質問 # 35
Which Class of Fires involves ordinary combustible materials such as paper, wood and cloth?
- A. Class B
- B. Class K
- C. Class D
- D. Class A
正解:D
質問 # 36
is the ability of a system or component to perform its required functions under stated conditions for a specified period of time.
- A. Availability
- B. Scalability
- C. Agility
- D. Reliability
正解:D
質問 # 37
Mean time between failures is best considered a measure of:
- A. Size
- B. Duration
- C. Cost
- D. Reliability
正解:D
質問 # 38
Which Class of Fires involves cooking appliances?
- A. Class B
- B. Class K
- C. Class A
- D. Class C
正解:B
質問 # 39
......