質問 # 31
Which of the following statements are true about a routing design that employs OSPF on the underlay network of a DC? (Select All that Apply)
- A. This routing design is recommended when the DC has more than 300 switches.
- B. Typically, the IP address of Loopback0 is configured as the VTEP IP address and the same IP address is planned for active-active leaf nodes in the same group.
- C. It is recommended that all devices be planned in Area 0.
- D. The network type of spine and leaf nodes can be set to P2P in order to accelerate convergence.
正解:B、D
解説:
OSPF (Open Shortest Path First) is a routing protocol used in the underlay network of Huawei's CloudFabric DCNs. Let's evaluate each statement:
A . Typically, the IP address of Loopback0 is configured as the VTEP IP address and the same IP address is planned for active-active leaf nodes in the same group: This is true. Loopback0 IP is commonly used as the VTEP IP for stability, and in active-active leaf node groups (e.g., M-LAG), the same IP can be configured with VRRP or anycast to ensure consistency. TRUE.
B . The network type of spine and leaf nodes can be set to P2P in order to accelerate convergence: This is true. Setting OSPF network type to Point-to-Point (P2P) on spine-leaf links reduces overhead (e.g., no DR/BDR election) and speeds up convergence, a recommended practice in Huawei DCNs. TRUE.
C . This routing design is recommended when the DC has more than 300 switches: This is false. OSPF is suitable for smaller to medium-sized DCNs (e.g., up to 200-300 switches). For larger networks (>300 switches), EBGP is preferred due to better scalability and reduced complexity. FALSE.
D . It is recommended that all devices be planned in Area 0: This is false. While a single Area 0 is possible for small DCNs, multi-area OSPF is recommended for larger networks to manage scalability and reduce routing table size, avoiding a flat Area 0 design. FALSE.
Thus, A and B are true statements about OSPF routing design in a DC underlay.
質問 # 32
Which of the following is not included in the physical architecture of a server?
- A. OS
- B. Application
- C. VMmonitor
- D. Hardware
正解:B
解説:
The physical architecture of a server refers to the tangible and low-level components that constitute the server itself, distinct from logical or software layers. Let's evaluate each option:
A . Application: Applications are software running on top of an operating system or virtual machine, not part of the server's physical architecture. They belong to the logical or user layer, not the physical structure. Not Included.
B . VMmonitor (Hypervisor): Assuming "VMmonitor" refers to a hypervisor (e.g., KVM or Xen), it's a software layer, but in Type-1 hypervisor scenarios, it runs directly on hardware, managing VMs. In Huawei's context, it's considered part of the server's operational architecture when deployed physically. Included.
C . OS (Operating System): The OS (e.g., Linux, Windows) runs directly on server hardware or within a VM. In bare-metal servers, it's a core component of the physical deployment. Included.
D . Hardware: Hardware (e.g., CPU, RAM, NICs, disks) is the foundational physical architecture of a server, providing the physical resources for all operations. Included.
Thus, A (Application) is not part of the physical architecture, as it's a higher-level software entity, not a physical component.
質問 # 33
Which of the following statements are true about IP address planning for a DC? (Select All that Apply)
- A. Service addresses refer to the IP addresses of servers, hosts, and gateways.
- B. IP address allocation should be simple and easy to manage, reflect network layers, and simplify network management and network expansion.
- C. IP addresses with a 24-bit mask are recommended for use as interconnection IP addresses.
- D. IP addresses must be contiguous. The routes with contiguous IP addresses can be summarized easily on a hierarchical network.
正解:A、B
解説:
IP address planning is critical in Huawei's CloudFabric data center networks to ensure scalability and efficiency. Let's evaluate each statement:
A . Service addresses refer to the IP addresses of servers, hosts, and gateways: This is true. Service addresses are assigned to endpoints (servers, hosts) and gateways, distinguishing them from management or interconnection IPs in DC planning. TRUE.
B . IP addresses with a 24-bit mask are recommended for use as interconnection IP addresses: This is false. A 24-bit mask (/24) is typically used for service subnets, while interconnection IPs (e.g., between spine and leaf) often use smaller masks (e.g., /31 or /30) to conserve addresses and align with point-to-point links. FALSE.
C . IP addresses must be contiguous. The routes with contiguous IP addresses can be summarized easily on a hierarchical network: This is false. Contiguity is desirable for summarization but not mandatory; non-contiguous blocks can still be managed with proper routing design (e.g., using BGP). FALSE.
D . IP address allocation should be simple and easy to manage, reflect network layers, and simplify network management and network expansion: This is true. Huawei recommends structured allocation (e.g., by layer or function) to streamline management and support future growth. TRUE.
Thus, A and D are true statements about IP address planning.
質問 # 34
Which of the following are advantages of iMaster NCE-FabricInsight's telemetry-based performance metric collection? (Select All that Apply)
- A. Efficient transmission
- B. One-off subscription and continuous data push
- C. Intelligent data analysis and automated troubleshooting
- D. Quasi-real-time data collection
正解:A、B、D
解説:
iMaster NCE-FabricInsight uses telemetry for performance metric collection, offering advanced monitoring in Huawei's CloudFabric Solution. Let's evaluate each option:
A . Efficient transmission: This is true. Telemetry uses streaming data (e.g., gRPC) to reduce overhead compared to traditional polling, enabling efficient transmission of metrics. TRUE.
B . Quasi-real-time data collection: This is true. Telemetry provides near-real-time data (e.g., sub-second updates), improving responsiveness over periodic SNMP polling. TRUE.
C . Intelligent data analysis and automated troubleshooting: This is false. While FabricInsight performs intelligent analysis, automated troubleshooting is a feature of the broader iMaster NCE platform, not specifically a telemetry advantage. Telemetry enables data collection, not the automation itself. FALSE.
D . One-off subscription and continuous data push: This is true. Telemetry operates on a subscription model where a one-time setup leads to continuous data push from devices, reducing manual intervention. TRUE.
Thus, A, B, and D are advantages of telemetry-based performance metric collection.
質問 # 35
Which of the following are the application scenarios of Huawei CloudFabric Solution? (Select All that Apply)
- A. OpenFlow network
- B. Hosting
- C. Computing
- D. Container network
- E. Cloud-network integration
正解:B、D、E
質問 # 36
A VXLAN tunnel is identified by a pair of VTEP IP addresses. During VXLAN tunnel establishment, the local and remote VTEPs attempt to obtain each other's IP addresses. If the VTEP IP addresses are reachable to each other at Layer 3, a VXLAN tunnel can be established.
- A. FALSE
- B. TRUE
正解:B
解説:
VXLAN (Virtual Extensible LAN) tunnels are used to encapsulate Layer 2 traffic over a Layer 3 network, a key feature in Huawei's data center solutions. The endpoints of a VXLAN tunnel are VXLAN Tunnel Endpoints (VTEPs), identified by their IP addresses.
Tunnel Identification: A VXLAN tunnel is uniquely identified by the pair of VTEP IP addresses (local and remote), along with the VNI (VXLAN Network Identifier). This pair ensures the tunnel is specific to the communication path between the two VTEPs.
Tunnel Establishment: During setup, VTEPs exchange information to learn each other's IP addresses. This can occur manually (static configuration) or dynamically (e.g., via BGP EVPN). The underlay network must provide Layer 3 reachability between the VTEP IP addresses, typically using routing protocols (e.g., OSPF, BGP) to ensure IP connectivity.
Reachability Condition: If the local and remote VTEP IP addresses are reachable at Layer 3, the tunnel can be established, allowing encapsulation and decapsulation of VXLAN traffic. This is a fundamental requirement in Huawei's VXLAN implementation.
The statement is TRUE (A) because a VXLAN tunnel's identification and establishment depend on reachable VTEP IP address pairs at Layer 3.
質問 # 37
Which of the following can be deployed to enhance DC reliability? (Select All that Apply)
- A. Monitor Link
- B. M-LAG
- C. Controller cluster
- D. Power supply redundancy
正解:B、C、D
解説:
Reliability in Huawei's CloudFabric data centers is enhanced through various mechanisms. Let's evaluate each option:
A . Power supply redundancy: This is true. Redundant power supplies (e.g., dual PSUs) ensure uninterrupted operation during power failures, a key reliability feature. TRUE.
B . M-LAG (Multi-Chassis Link Aggregation): This is true. M-LAG provides high availability by allowing active-active forwarding and failover between switches, enhancing network reliability. TRUE.
C . Monitor Link: This is false. Monitor Link is a Huawei feature for link status monitoring, not a direct reliability enhancement mechanism like redundancy or clustering. FALSE.
D . Controller cluster: This is true. A clustered SDN controller (e.g., iMaster NCE-Fabric) ensures high availability and failover, improving network management reliability. TRUE.
Thus, A, B, and D enhance DC reliability.
質問 # 38
M-LAG configuration consistency check classifies device configurations into key configurations (Type 1) and common configurations (Type 2). This check can be performed in strict or loose mode based on the processing mode when key configurations are inconsistent. Which of the following statements is false about M-LAG configuration consistency check?
- A. In loose mode, if Type 1 configurations of the two M-LAG member devices are inconsistent, the member interface on the M-LAG backup device is in Error-Down state and an alarm is generated, indicating that Type 1 configurations on the two devices are inconsistent.
- B. If Type 1 configurations of the two M-LAG member devices are inconsistent, certain problems may occur, such as loops and long-period packet loss when the status is normal.
- C. If Type 2 configurations of the two M-LAG member devices are inconsistent, an alarm that indicates key and common configuration inconsistencies is generated.
- D. If Type 2 configurations of the two M-LAG member devices are inconsistent, the M-LAG running status may be abnormal. Compared with Type 1 configuration problems, Type 2 configuration problems are more likely to be detected and have less impact on the network.
正解:C
解説:
To identify the false statement, we evaluate each option based on standard M-LAG documentation, such as Huawei's and Arista's guidelines, which are commonly referenced in HCIP-Data Center Network training.
Option A: In loose mode, if Type 1 configurations of the two M-LAG member devices are inconsistent, the member interface on the M-LAG backup device is in Error-Down state and an alarm is generated, indicating that Type 1 configurations on the two devices are inconsistent.
Evaluation: This statement is true. In loose mode, inconsistencies in Type 1 (key) configurations are still critical, as they can affect M-LAG operation. According to Huawei M-LAG Configuration Guide, when Type 1 configurations are inconsistent in loose mode, the system may place the member interface on the backup device into an Error-Down state and generate an alarm to alert administrators. This ensures that critical issues are flagged, even in loose mode, to prevent loops or packet loss.
Conclusion: True.
Option B: If Type 1 configurations of the two M-LAG member devices are inconsistent, certain problems may occur, such as loops and long-period packet loss when the status is normal.
Evaluation: This statement is true. Type 1 configurations are essential for M-LAG operation, and inconsistencies can lead to severe network issues. For example, mismatched LACP settings or VLAN mappings can create loops or cause packet loss, as noted in Arista M-LAG Documentation. These problems can persist even when the system appears normal, making consistency checks critical for troubleshooting and O&M.
Conclusion: True.
Option C: If Type 2 configurations of the two M-LAG member devices are inconsistent, the M-LAG running status may be abnormal. Compared with Type 1 configuration problems, Type 2 configuration problems are more likely to be detected and have less impact on the network.
Evaluation: This statement is true. Type 2 (common) configurations, such as QoS or STP settings, are less critical but can still affect network performance. According to Huawei M-LAG Best Practices, Type 2 inconsistencies are often detected during consistency checks but have a lower impact on M-LAG operation compared to Type 1 issues. They are also more likely to be flagged during monitoring, as they are less severe and easier to resolve.
Conclusion: True.
Option D: If Type 2 configurations of the two M-LAG member devices are inconsistent, an alarm that indicates key and common configuration inconsistencies is generated.
Evaluation: This statement is false. While Type 2 (common) configuration inconsistencies are detected during consistency checks, they do not typically trigger alarms, especially alarms that specifically indicate both key and common configuration inconsistencies. According to Huawei M-LAG Configuration Guide and Arista M-LAG Documentation, Type 2 inconsistencies may be logged or reported in system logs but are not severe enough to generate critical alarms unless they significantly impact network operation. Alarms are more commonly associated with Type 1 (key) configuration inconsistencies, as they pose a higher risk to M-LAG functionality.
Conclusion: False.
質問 # 39
Which of the following nodes is a backbone node of a DC and provides high-speed IP forwarding?
- A. DC1 leaf
- B. Border leaf
- C. Spine
- D. Service leaf
正解:C
解説:
In Huawei's spine-leaf DCN architecture, nodes have distinct roles:
A . Spine: The spine nodes form the backbone of the data center, providing high-speed IP forwarding between leaf nodes. They handle east-west traffic with non-blocking connectivity, making them the core backbone nodes. Correct.
B . DC1 leaf: This is not a standard node type; it may be a typo or misnomer. Leaf nodes connect to endpoints, not act as backbones. Incorrect.
C . Service leaf: Service leaf nodes connect to internal services (e.g., servers), not the backbone, focusing on access rather than high-speed forwarding. Incorrect.
D . Border leaf: Border leaf nodes connect to external networks, handling routing, not serving as the internal backbone. Incorrect.
Thus, the answer is A (Spine).
質問 # 40
Which of the following statements is false about VM service traffic in the computing scenario?
- A. Traffic between vSwitches on virtual servers and server leaf nodes is VLAN encapsulated.
- B. Inter-VPC traffic must pass through the firewall.
- C. Traffic between VAS devices and service leaf nodes is VLAN encapsulated.
- D. Traffic inside a fabric is VXLAN encapsulated.
正解:B
解説:
In Huawei's CloudFabric computing scenario, VM service traffic involves virtualized environments with VXLAN overlays and traditional VLANs. Let's evaluate each statement:
A . Traffic inside a fabric is VXLAN encapsulated: This is true. Within a CloudFabric network, VXLAN encapsulation is used to transport traffic across the fabric, enabling overlay networking for VMs. TRUE.
B . Inter-VPC traffic must pass through the firewall: This is false. Inter-VPC (Virtual Private Cloud) traffic can be routed directly between VPCs using a gateway or router (e.g., with EVPN Type 5 routes) without necessarily passing through a firewall, depending on security policies. Firewalls are optional for inter-VPC traffic, not mandatory. FALSE.
C . Traffic between VAS devices and service leaf nodes is VLAN encapsulated: This is true. Value-Added Services (VAS) devices (e.g., load balancers) often connect to service leaf nodes using VLAN encapsulation, especially in traditional or hybrid deployments. TRUE.
D . Traffic between vSwitches on virtual servers and server leaf nodes is VLAN encapsulated: This is true. Traffic from virtual switches (vSwitches) on hypervisors to physical server leaf nodes typically uses VLAN encapsulation over the physical NICs, before VXLAN overlay if applicable. TRUE.
Thus, B is the false statement because inter-VPC traffic does not always require a firewall.
質問 # 41
Which of the following servers are built into iMaster NCE-Fabric to provide related services? (Select All that Apply)
- A. RADIUS authentication server
- B. DNS server
- C. Version file server
- D. DHCP server
正解:C、D
解説:
Huawei's iMaster NCE-Fabric is an SDN controller for the CloudFabric Solution, providing network orchestration and management. It includes built-in servers to support its operations. Let's evaluate each option:
A . DNS server: This is false. iMaster NCE-Fabric does not include a built-in DNS server; it relies on external DNS services for name resolution, configured during deployment. FALSE.
B . RADIUS authentication server: This is false. RADIUS authentication is typically handled by external AAA servers; iMaster NCE-Fabric integrates with them but does not embed a RADIUS server. FALSE.
C . DHCP server: This is true. iMaster NCE-Fabric includes a built-in DHCP server to assign temporary IP addresses during Zero Touch Provisioning (ZTP) or initial device configuration. TRUE.
D . Version file server: This is true. A version file server is built into iMaster NCE-Fabric to store and deliver software images or configuration files for device upgrades and management. TRUE.
Thus, C (DHCP server) and D (Version file server) are built into iMaster NCE-Fabric.
質問 # 42
Which of the following are the application scenarios of Huawei CloudFabric Solution? (Select All that Apply)
- A. OpenFlow network
- B. Hosting
- C. Computing
- D. Container network
- E. Cloud-network integration
正解:B、D、E
解説:
Huawei's CloudFabric Solution supports various data center scenarios. Let's evaluate each option:
A . Container network: This is true. CloudFabric supports containerized environments (e.g., Kubernetes) with VXLAN and SDN integration. TRUE.
B . OpenFlow network: This is false. CloudFabric primarily uses BGP-EVPN and proprietary protocols, not OpenFlow, which is more associated with other SDN platforms. FALSE.
C . Hosting: This is true. CloudFabric is suitable for hosting environments, providing multi-tenant network services. TRUE.
D . Cloud-network integration: This is true. It integrates with cloud platforms (e.g., OpenStack) for unified management. TRUE.
E . Computing: This is false. While it supports computing resources, "computing" is not a primary scenario; it's an enabler (e.g., server connectivity). FALSE.
Thus, A, C, and D are application scenarios.
質問 # 43
In the computing scenario of Huawei CloudFabric Solution, which of the following services are optional for controller interconnection? (Select All that Apply)
- A. Interconnection with the authentication server
- B. Interconnection with the VMM
- C. Interconnection with FabricInsight
- D. Interconnection with eSight
正解:C、D
解説:
In Huawei's CloudFabric Solution, the iMaster NCE-Fabric controller manages the network in computing scenarios (e.g., virtualized environments). Controller interconnection with external systems can be mandatory or optional depending on functionality. Let's evaluate each option:
A . Interconnection with FabricInsight: This is optional. FabricInsight is an analytics and assurance tool that enhances visibility and troubleshooting but is not required for basic controller operations in the computing scenario. OPTIONAL.
B . Interconnection with the authentication server: This is mandatory. Authentication servers (e.g., RADIUS, TACACS+) are essential for securing access to the controller and managed devices, a core requirement in computing scenarios. NOT OPTIONAL.
C . Interconnection with eSight: This is optional. eSight is a network management platform that provides additional monitoring and management capabilities, but it is not necessary for core controller functionality. OPTIONAL.
D . Interconnection with the VMM (Virtual Machine Manager): This is mandatory. Interconnection with a VMM (e.g., FusionCompute, OpenStack) is required to manage virtualized computing resources and orchestrate network services in the computing scenario. NOT OPTIONAL.
Thus, A (Interconnection with FabricInsight) and C (Interconnection with eSight) are optional services for controller interconnection.
質問 # 44
Which of the following statements are true about the tenant service model? (Select All that Apply)
- A. One logical router is mapped to one VRF.
- B. A tenant can apply for independent compute, storage, and network resources.
- C. An EPG can have only one subnet.
- D. A subnet supports the access of only one VM.
正解:A、B
解説:
The tenant service model in Huawei's data center networks (e.g., CloudFabric with SDN) organizes resources for multi-tenancy. Let's evaluate each statement:
A . A tenant can apply for independent compute, storage, and network resources: This is true. Tenants in a multi-tenant environment can request isolated compute (VMs), storage (volumes), and network (VLANs/VXLAN VNIs) resources, a core feature of Huawei's tenant isolation model. TRUE.
B . One logical router is mapped to one VRF: This is true. A Virtual Routing and Forwarding (VRF) instance is associated with a logical router to provide isolated Layer 3 routing for a tenant, a standard practice in Huawei's network virtualization. TRUE.
C . An EPG can have only one subnet: This is false. An Endpoint Group (EPG) in Huawei's ACI-like models can span multiple subnets, grouping endpoints (e.g., VMs) based on policies, not limited to a single subnet. FALSE.
D . A subnet supports the access of only one VM: This is false. A subnet can support multiple VMs, as it defines an IP address range for a network segment, not a one-to-one VM mapping. FALSE.
Thus, A and B are true statements about the tenant service model.
質問 # 45
In network overlay, both endpoints of a VXLAN tunnel are physical switches.
- A. TRUE
- B. FALSE
正解:B
解説:
In a network overlay, VXLAN (Virtual Extensible LAN) tunnels extend Layer 2 networks over a Layer 3 underlay, commonly implemented in Huawei's data center solutions. The endpoints of a VXLAN tunnel are VXLAN Tunnel Endpoints (VTEPs), which encapsulate and decapsulate traffic.
VTEP Roles: VTEPs can be physical switches (e.g., Huawei CloudEngine series), virtual switches (e.g., Open vSwitch on a hypervisor), or routers with VXLAN support. The endpoints are defined by their IP addresses, not their physical nature.
Deployment Flexibility: In modern data centers, VXLAN tunnels often connect physical switches to virtualized environments where VTEPs reside on hypervisors or servers hosting VMs. For example, a VM's vNIC might connect to a virtual switch (VTEP) that tunnels to a physical switch VTEP. Thus, both endpoints are not always physical switches; one or both can be virtual.
The statement is FALSE (B) because both endpoints of a VXLAN tunnel are not necessarily physical switches; they can include virtual VTEPs in hypervisors or other devices.
質問 # 46
In the CloudFabric Solution, SecoManager and iMaster NCE-Fabric are deployed independently. After SecoManager is installed, it needs to be manually interconnected with iMaster NCE-Fabric.
- A. TRUE
- B. FALSE
正解:B
解説:
In Huawei's CloudFabric Solution, SecoManager (Security Manager) and iMaster NCE-Fabric (Network Controller) are components of the SDN ecosystem. SecoManager handles security policy management, while iMaster NCE-Fabric manages network orchestration.
Deployment: These components can be deployed independently but are designed to integrate seamlessly. Huawei's architecture supports automated interconnection after installation, leveraging northbound/southbound APIs or pre-configured integration workflows.
Interconnection: Manual interconnection is not required post-installation; the system automates the process once both are deployed and configured within the same management domain (e.g., via IP addressing and authentication).
The statement is FALSE (B) because interconnection is automated, not manual.
質問 # 47
Assume that a VXLAN tunnel is monitored on a Huawei CE series switch and that the tunnel status is Down or the tunnel fails to be dynamically established. In this scenario, which of the following statements are true about how to check the cause of the fault? (Select All that Apply)
- A. Run the display vxlan statistics command to check the cause of the fault.
- B. Run the display vxlan troubleshooting command to check at most the latest five reasons why a VXLAN tunnel goes Down.
- C. Run the display vxlan peer command to check the cause of the fault on the peer device of the tunnel.
- D. Run the display vxlan troubleshooting command to check the causes of at most the latest five failures to dynamically establish a VXLAN tunnel.
正解:A、B、C、D
解説:
On Huawei CloudEngine (CE) series switches, VXLAN tunnel monitoring and troubleshooting involve specific commands to diagnose issues such as tunnel Down status or failed dynamic establishment. Let's evaluate each option:
A . Run the display vxlan statistics command to check the cause of the fault: This command provides statistics on VXLAN tunnel traffic, including packet drops, encapsulation/decapsulation counts, and errors. It helps identify issues like misconfiguration or network congestion, making it a valid troubleshooting tool. TRUE.
B . Run the display vxlan peer command to check the cause of the fault on the peer device of the tunnel: This command displays information about VXLAN peers, including their IP addresses, VNIs, and reachability status. Checking the peer device's status can reveal connectivity or configuration mismatches, aiding fault diagnosis. TRUE.
C . Run the display vxlan troubleshooting command to check the causes of at most the latest five failures to dynamically establish a VXLAN tunnel: This command logs and displays troubleshooting details, including the latest five failure reasons for dynamic tunnel setup (e.g., BGP EVPN issues or reachability problems). This is a standard feature on Huawei CE switches. TRUE.
D . Run the display vxlan troubleshooting command to check at most the latest five reasons why a VXLAN tunnel goes Down: This command also tracks reasons for tunnel Down events (e.g., underlay failure, peer unreachability), limited to the latest five incidents. This is consistent with Huawei's troubleshooting capabilities. TRUE.
All options A, B, C, and D are true, as they represent valid commands and approaches to troubleshoot VXLAN tunnel issues on Huawei CE switches.
質問 # 48
Which of the following can be used as the conditions for microsegmentation to divide EPGs? (Select All that Apply)
- A. VM name
- B. Operating system
- C. MAC address
- D. IP address
正解:A、B、C、D
解説:
Microsegmentation in Huawei's data center networks (e.g., CloudFabric with SDN) divides Endpoint Groups (EPGs) to enforce fine-grained security policies. EPGs group endpoints (e.g., VMs) based on attributes. Let's evaluate each option:
A . Operating system: This is true. The OS type (e.g., Linux, Windows) can be used to segment EPGs, enabling policy enforcement based on OS-specific security needs. TRUE.
B . VM name: This is true. VM names can be used as identifiers for microsegmentation, allowing policies to target specific VMs. TRUE.
C . IP address: This is true. IP addresses are commonly used to define EPG boundaries, especially for network-based segmentation. TRUE.
D . MAC address: This is true. MAC addresses can segment EPGs, particularly for Layer 2-based policies or device-specific isolation. TRUE.
All options A, B, C, and D are valid conditions for microsegmentation to divide EPGs in Huawei's implementation.
質問 # 49
Which of the following statements are true about the Easy mode? (Select All that Apply)
- A. iMaster NCE-Fabric automatically generates configuration script files.
- B. Layer 2 and Layer 3 basic services in a VPC are orchestrated on the Easy page.
- C. This mode has low networking requirements.
- D. On iMaster NCE-Fabric, you need to manually create and configure fabric resource pools, managed devices, device groups, device roles, tenants, and VPCs one by one in the Configuration Wizard menu.
正解:A、B、C
解説:
The Easy mode in Huawei's iMaster NCE-Fabric simplifies network deployment for basic VXLAN fabrics. Let's evaluate each statement:
A . This mode has low networking requirements: This is true. Easy mode is designed for simple topologies (e.g., small spine-leaf networks) with minimal configuration complexity. TRUE.
B . iMaster NCE-Fabric automatically generates configuration script files: This is true. Easy mode automates script generation based on user inputs, reducing manual effort. TRUE.
C . On iMaster NCE-Fabric, you need to manually create and configure fabric resource pools, managed devices, device groups, device roles, tenants, and VPCs one by one in the Configuration Wizard menu: This is false. Easy mode automates these tasks, minimizing manual configuration compared to advanced modes. FALSE.
D . Layer 2 and Layer 3 basic services in a VPC are orchestrated on the Easy page: This is true. Easy mode supports automated orchestration of L2 (e.g., BDs) and L3 (e.g., gateways) services within a VPC. TRUE.
Thus, A, B, and D are true statements about Easy mode.
質問 # 50
Which of the following technologies are open-source virtualization technologies? (Select All that Apply)
- A. KVM
- B. FusionSphere
- C. Hyper-V
- D. Xen
正解:A、D
解説:
Virtualization technologies enable the creation of virtual machines (VMs) by abstracting hardware resources. Open-source technologies are freely available with accessible source code. Let's evaluate each option:
A . Hyper-V: Hyper-V is a hypervisor developed by Microsoft, integrated into Windows Server and available as a standalone product. It is proprietary, not open-source, as its source code is not publicly available. Not Open-Source.
B . Xen: Xen is an open-source hypervisor maintained by the Xen Project under the Linux Foundation. It supports multiple guest operating systems and is widely used in cloud environments (e.g., Citrix XenServer builds on it). Its source code is freely available. Open-Source.
C . FusionSphere: FusionSphere is Huawei's proprietary virtualization and cloud computing platform, based on OpenStack and other components. While it integrates open-source elements (e.g., KVM), FusionSphere itself is a commercial product, not fully open-source. Not Open-Source.
D . KVM (Kernel-based Virtual Machine): KVM is an open-source virtualization technology integrated into the Linux kernel. It turns Linux into a Type-1 hypervisor, and its source code is available under the GNU General Public License. It's widely used in Huawei's virtualization solutions. Open-Source.
Thus, B (Xen) and D (KVM) are open-source virtualization technologies.
質問 # 51
An enterprise builds a DC and deploys iMaster NCE-Fabric to automatically deliver network configurations. After the engineer manually deploys the underlay network and delivers overlay network configurations through iMaster NCE-Fabric, it is found that tenant hosts cannot access external networks. Which of the following is not a possible cause of this fault?
- A. No return route is configured on the PE.
- B. The engineer did not check whether the service loopback interface needs to be configured on the VXLAN network based on the switch model.
- C. No firewall security policy is configured when host traffic passes through the firewall.
- D. The MAC address of the NVE interface on the VXLAN network is not manually specified.
正解:D
解説:
In Huawei's CloudFabric Solution, iMaster NCE-Fabric automates overlay network (e.g., VXLAN) configuration, while the underlay network is manually deployed. Tenant hosts failing to access external networks indicate a connectivity issue, likely at the overlay-underlay boundary or security layer. Let's evaluate each option as a possible cause:
A . No return route is configured on the PE: This is a possible cause. The Provider Edge (PE) device (e.g., border leaf or router) must have a return route to the tenant's VXLAN network for external access. Without it, traffic from external networks cannot reach the DC. POSSIBLE CAUSE.
B . The engineer did not check whether the service loopback interface needs to be configured on the VXLAN network based on the switch model: This is a possible cause. Some Huawei switch models (e.g., CE series) require a service loopback interface as the VTEP source IP. If omitted or misconfigured based on the model, external connectivity fails. POSSIBLE CAUSE.
C . No firewall security policy is configured when host traffic passes through the firewall: This is a possible cause. If a firewall is in the path (e.g., between tenant VPC and external network), a missing security policy (e.g., allowing outbound traffic) blocks access. POSSIBLE CAUSE.
D . The MAC address of the NVE interface on the VXLAN network is not manually specified: This is not a possible cause. The Network Virtualization Edge (NVE) interface in VXLAN does not require a manually specified MAC address; it uses the switch's system MAC or auto-generates one. iMaster NCE-Fabric typically handles this automatically, and manual specification is neither required nor a common fault point for external access issues. NOT A POSSIBLE CAUSE.
Thus, D is not a possible cause of the fault.
質問 # 52
Fill in blank
The FusionCompute logical architecture consists of two modules: ___ and CNA. (Enter the acronym in uppercase letters.)
正解:
解説:
VRM
Explanation:
FusionCompute is Huawei's virtualization platform, part of the FusionSphere ecosystem, designed for managing virtualized resources in data centers. Its logical architecture consists of two primary modules:
VRM (Virtualization Resource Management): VRM is the management module responsible for centralized control, resource allocation, and monitoring of virtual machines, hosts, and clusters. It provides the user interface and orchestration capabilities for administrators to manage the virtualized environment.
CNA (Compute Node Agent): CNA runs on physical hosts and handles the execution of virtualization tasks, such as VM creation, resource scheduling, and communication with the underlying hypervisor (typically KVM in Huawei's implementation). It acts as the compute node agent interfacing with the hardware.
Together, VRM and CNA form the core logical architecture of FusionCompute, with VRM managing the environment and CNA executing the compute tasks. The answer, per Huawei's documentation, is VRM.