NS0-520無料試験問題と解答PDF最新問題2022年01月 [Q13-Q30]

Share

NS0-520無料試験問題と解答PDF最新問題2022年01月

最新NS0-520試験問題集で最近更新された236問題

質問 13
A4-node ONTAP FAS9000 cluster was used to serve I/O from six RedHat 7.3 servers. The servers were configured with maximum, queue depth.
For production purposes, an additional 60 similarly configured hosts were added to the environment. Later, the hosts started reporting random QFull errors, and the aggregated performance degraded.
Which two solutions would alleviate the QFull errors and performance problems? (Choose two.)

  • A. Reduce FC HBA gueue depth on the hosts.
  • B. Remove Selective LUN Mapping (SIM) from the 4-node FAS9000 cluster.
  • C. Download the latest FC HBA driver, firmware, and BIOS, and deploy them on the hosts.
  • D. Configure and use additional FC target HBAs in the FAS9000 cluster.

正解: A,D

 

質問 14
Click the Exhibit button.

You have three Linux hosts that are FC multipath connected to an AFF All SAN Array A700. A failover test is performed by shutting down both Fabric A and N2, as shown in the exhibit.
Referring to this exhibit, what happens to the remaining paths from the Linux hosts to the ASA A700 target?

  • A. All paths go offline from the double failure of the switch and node.
  • B. Half of the paths are active-non-optimized (ANO) and the other half are active-optimized (AO).
  • C. All paths are active-optimized (AO).
  • D. All paths are active-non-optimized (ANO).

正解: C

 

質問 15
An administrator wants to connect a DS460C disk shelf to a FAS9000.
Which two statements are correct in this scenario? (Choose two.)

  • A. A deep rack is required
  • B. A C13/C14 power cable and compatible rack power distribution unit are required.
  • C. A C19/C20 power cable and compatible rack power distribution unit are required.
  • D. A Telco rack is required

正解: A,C

 

質問 16
An administrator is configuring a SAN-only cluster. The data room that houses four AFF A220 controllers is small and not able to house the DS224C shelves. The administrator proposes to rack the shelves in a separate room that is 40 meters away from the controllers.
In this situation, how would you properly cable the controllers to the shelves?

  • A. Use multimode active copper cables.
  • B. Use multimode active optical cables.
  • C. Use multimode passive copper cables.
  • D. Use multimode passive optical cables.

正解: B

 

質問 17
In an NVMe/FC environment, the host cannot discover the namespace on the AFF system. Referring to the exhibit, what is the problem?

  • A. The NVMe service is not running on the SVM
  • B. The host MPIO drivers are not installed
  • C. NVMe is not supported on the FC adapter
  • D. The NQN is not correct

正解: D

解説:
We would not be able to run that command if NVMe is not enabled
NVMe is supported on the same SVM along with FC protocol
The multipath tool on NVMe is called ANA
NQN needs to be correctly declared on the subsystem to map the new NVMe resources

 

質問 18
While expanding a 200 GB LUN in an ONTAP 9.4 system, the following error is observed:

What is the cause of this error?

  • A. The LUN can be expanded up to 10 times its original size.
  • B. The volume auto-grow is disabled.
  • C. Space reservation is enabled.
  • D. The LUN reached maximum capacity.

正解: B

 

質問 19
You are configuring a Windows Server 2019 system to attach to an ISCSI presented LUN. There are multiple physical paths from the Windows Server to the Netapp Cluster. Which two changes are required to the Windows Server to enable multipath? (choose two)

  • A. Add a converged network adapter (CNA)
  • B. Select the "enable multi-path" checkbox on the ISCSI software initiator
  • C. Add an Ethernet network adapter
  • D. Enable MPIO by selecting the option in the MPIO properties administrative application

正解: B,D

解説:
Select Enable multi-path, select Automatically restore this connection when the computer starts or Add this connection to the list of Favorite Targets, and then click Advanced You can find more information on this link:
https://docs.netapp.com/ontap-9/topic/com.netapp.doc.exp-iscsi-cpg/iSCSI%20express%20configuration%20for%20Windows.pdf (15)

 

質問 20
A customer wants to deploy NVMe/FC along with an existing FC SAN fabric using ONTAP 9.8. In this scenario, which two actions are correct? (choose two)

  • A. Use existing zoning on fabric switches
  • B. Enable NVMe/FC on the existing FC SVM
  • C. Create new zoning on fabric switches
  • D. Upgrade your FC switches from 16GB to 32GB

正解: A,B

解説:
Because NVMe/FC simply swaps command sets from SCSI to NVMe, it is an easy transition to make. NVMe/FC uses the same FC transport and therefore the same hardware from the host, through the switch and all the way to the NVMe/FC target port on the storage array. Thus, NVMe/FC implementations can use existing FC infrastructure, including HBAs, switches, zones, targets, and cabling.
You can find more information on this link:
https://www.netapp.com/de/media/10681-tr4684.pdf

 

質問 21
You need to move a LUN non-disruptively from an AFF A200 HA pair to an AFF A700 HA pair within the same 4-node cluster using the steps shown below.
1. Scan the host OS to discover all paths to the LUN.
2. Execute the lun move command to move the LUN to the AFF A/00 HA pair.
3. Remove the AFF A200 HA pair from the reporting-nodes list.
4. Add the AFF A700 HA pair to the reporting-nodes list.
What is the correct sequence in performing, these steps?

  • A. 4, 3. 2. 1
  • B. 3, 2, 1,4
  • C. 4. 1, 2, 3
  • D. 1, 2, 3. 4

正解: C

 

質問 22
You are in the testing phase of a newly deployed NVMe over Fibre Channel (NVMe/FC) SAM environment using Asynchronous Namespace Access (ANA). You are unable to successfully fail over a workload.
In this scenario, which action should you perform?

  • A. Verify that the host operating system version supports ANA.
  • B. Verify that the NVMe/FC host utilities kit is installed for ANA.
  • C. Verify that multi-initiator zoning is configured on the FC switches.
  • D. Verify that the DM-Multipath driver is configured for ANA.

正解: D

 

質問 23
You want to move a SAN LIF and preserve its configuration information and avoid rezoning the switch fabric. In this scenario, which two steps must be performed to fulfill this goal? (Choose two)

  • A. Move the SAN LIF to another node in a cluster on existing storage virtual machine (SVMs)
  • B. Keep the SAN LIF online before it is moved
  • C. Move the SAN LIF to another node in a cluster on a different storage virtual machine (SVMs)
  • D. Take the SAN LIF offline before it is moved

正解: A,D

解説:
Moving SAN LIFs
If a node needs to be taken offline, you can move a SAN LIF to preserve its configuration information, such as its WWPN, and avoid rezoning the switch fabric. Because a SAN LIF must be taken offline before it is moved, host traffic must rely on host multipathing software to provide nondisruptive access to the LUN. You can move SAN LIFs to any node in a cluster, but you cannot move the SAN LIFs between storage virtual machines (SVMs).
Yoy can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-09F5C2A3-FA66-4252-BEEF-D556A143CD30.html

 

質問 24
An administrator is planning a hardware refresh and data migration from a Data ONTAP 7.3 system to new AFF A3-00 cluster that is using ONTAP 9.0. The Mode system only serves FC LUNs to a Windows 2012Rs server cluster that needs to remain connected after migration Referring to the scenario, which method would be used for the LUN migration.

  • A. Foreign LUN import (FLI)
  • B. 7-Mode Transition Tool (7MIT)
  • C. Unified Host Utility Kit
  • D. Oncommand system Manager

正解: B

 

質問 25
An administrator is asked to provision a SAN environment in which host applications can monitor LUN space and performance space reclamation.
Which LUN type would satisfy these requirements?

  • A. SCSI thick provisioned LUN
  • B. SCSI thin provisioned LUN
  • C. NetApp thin provisioned volume
  • D. NetApp thick provisioned volume

正解: B

解説:
Automatic host-side space management with SCSI thinly provisioned LUNs
If your host supports SCSI thin provisioning, you can enable the space-allocation option in ONTAP to turn on automatic host-side space management.
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-93D78975-6911-4EF5-BA4E-80E64B922D09.html

 

質問 26
Which option needs to be set on a LUN to guarantee that it cannot be affected by other LUNs in the volume?

  • A. Volume Guarantee
  • B. LUN Reservation Disabled
  • C. Volume Space Reserved
  • D. LUN Reservation Enabled

正解: D

 

質問 27
You are configuring FC ports on front-end SAN switches for a 4-node Metrocluster configuration across two data centers. You need to ensure that each data center serves FC LUNs when an FC port goes offline in one data center. In this scenario, which front end switch setting must be modified to avoid overlap when a new port comes online?

  • A. WWPN reject
  • B. ANA mapped
  • C. NPIV enabled
  • D. WWNN reject
  • E. NPIV reject

正解: C

解説:
Best practice: NPIV is required for FC LIFs to operate correctly. Before creating FC LIFs, make sure that any fabrics attached to an ONTAP system have NPIV enabled.
You can find more information on this link:
https://www.netapp.com/pdf.html?item=/media/10680-tr4080pdf.pdf

 

質問 28
You connected your FAS8200 to a Brocade SAN switch. As shown in the exhibit, port 0e is not available.
In this scenario, which statement is correct?

  • A. The switch port is configured for mode E_Port.
  • B. The incorrect SFP+ module is installed.
  • C. The switch zoning is using the FC nodename.
  • D. The incorrect firmware revision is installed.

正解: A

 

質問 29
Click the Exhibit button.

You need to perform an automated non-disruptive upgrade from ONTAP 9.5 to ONTAP 9.7.
Referring to the exhibit, which tool would be used?

  • A. Perfstat
  • B. AutoSupport OnDemand
  • C. Upgrade Advisor
  • D. OneCollect

正解: C

 

質問 30
......


Network Appliance NS0-520 認定試験の出題範囲:

トピック出題範囲
トピック 1
  • トラブルシューティングタスクの知識を示します
  • 環境および物理的な考慮事項を特定します
トピック 2
  • ONTAPSANの実装と構成
  • スイッチ構成の概念の説明
トピック 3
  • SVM構成タスクの知識を示す
  • ストレージコントローラー構成の概念を説明する
トピック 4
  • ONTAPSAN実装のテストとトラブルシューティング
  • SANコンポーネントの詳細なインベントリを特定する

 

Network Appliance NS0-520リアル2022年最新のブレーン問題集で模擬試験問題集:https://www.goshiken.com/NetworkAppliance/NS0-520-mondaishu.html