100%更新されたのはCisco 300-615限定版PDF問題集 [Q49-Q72]

Share

100%更新されたのはCisco 300-615限定版PDF問題集

有効な試験問題を試そう300-615には無料サイトで限定お試しチャンス


シスコ300-615試験は、Cisco NX-OS、Cisco ACI、Cisco MDS、およびCisco UCSなどの高度なトラブルシューティング手法、プロトコル、およびテクノロジーに関する候補者の知識をテストします。この試験は、ネットワーク、ストレージ、コンピューティング、および仮想化に関連する問題を特定し、解決する候補者の能力も評価します。

 

質問 # 49
A network engineer must configure SNMP monitoring on the Cisco Nexus 5000 Series Switch.
The engineer issues the SNMP-server user testuser enforcePriv command but receives this message: "Unable to update CLI users database". Which change to permissions for testuser resolves the issue?

  • A. Restrict read permission.
  • B. Restrict write permission.
  • C. Add write permission.
  • D. Add read permission.

正解:C


質問 # 50
The script fails to convert a JSON variable into a Python dictionary. Which action resolves the issue?

  • A. Define a json_output as a YAML object, yaml json_output
  • B. Use a json.dumps(json_output) function
  • C. Invoke a function yaml.loads(json._output ,decoder_"json")
  • D. Fix the JSON syntax by modifying "attribures" to "attribures":

正解:D


質問 # 51
If no traffic was ever sent across the overlay, what will the show mac address-table command on the OTV VDC indicate?

  • A. the system IDs of all the local OTV edge devices
  • B. all the MAC addresses learned on the extended VLAN
  • C. invalid command
  • D. the MAC address of the local OTV join interface
  • E. the system IDs of all the local and remote edge devices in the overlay

正解:D


質問 # 52
Refer to the exhibit. You see the fault when configuring a global ID pool on Cisco UCS Central.
Which scenario could cause the issue?

  • A. The same ID is defined in Cisco UCS Central and Cisco UCS Manager.
  • B. The same ID is assigned to the service profiles in two registered domains.
  • C. The same IP address is configured in two registered domains.
  • D. Global service profiles consume IDs from the blocks that have an assigned ID range qualifier

正解:B

解説:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-central/troubleshooting/Cisco-UCS-Central_Troubleshooting_Reference/Cisco-UCS- Central_Troubleshooting_Reference_chapter_0100.html#concept_DBE0AD18AEBA411EA7B09
65AE2E7A0BD


質問 # 53
An engineer troubleshoots a packet flow from an access leaf to a spine. Which EVPN routes are expected on this connection?

  • A. EVPN Type 9-15
  • B. EVPN Type 0, 9, and 15
  • C. EVPN Type 0 and 16
  • D. EVPN Type 1-5

正解:D

解説:
Section: Network
Explanation


質問 # 54
Cisco Unified Computing System Manager raises a critical error message that indicates that the system has overlapping Ethernet and FCoE VLANs. All of the Ethernet traffic on the overlapping VLANs drops. Which action resolves the issue?

  • A. Change the PIN groups on the vHBAs.
  • B. Set the FCoE VLAN as the native VLAN on server uplinks.
  • C. Modify the FCoE VLAN.
  • D. Modify the VLAN assignment to vNICs.

正解:C

解説:
Reassigning the VLAN to different vNICs doesn't solve the original problem of having Ethernet and FCOE interfaces with overlapping VLAN IDs. Changing the FCOE VLAN ID makes the most sense.


質問 # 55
An engineer troubleshoots a VXLAN EVPN data center. The applications in the data center fail to reach the DNS server that is located at IP 10.10.10.10. The engineer examines the BGP EVPN routing table and notes that the IP prefix route covers the DNS server is missing. Which action resolve the issue?

  • A. Configure an IP ARP entry to represent [4]:[0300.0000.00fc.bd00.0309l[32]:[10.10.10.10]/136,n the routing table
  • B. Set the IP prefix route to represent [5]:[0]:[0]:[32]:[10.10.10.10]/224 in the routing table.
  • C. Set the IP prefix route to represent [2]:[0]:[0]:[48]:[0050.569f.1285]:[0]:[0.0.0.0]/216 in the routing table
  • D. Configure an IP ARP entry to represent [2]:[0]:[0]:[48]:[0050.569f.1285]:[32]:[10.10.10.10]/272 in the routing table

正解:B


質問 # 56
An IOM fails during a firmware upgrade and is unresponsive. Which action recovers the module?

  • A. From the peer IOM, reset the faulty module.
  • B. Restore UCSM configuration from backup.
  • C. Use AutoInstall to reinstall the firmware.
  • D. Roll back to the previous firmware.

正解:D

解説:
Section: Management and Operations
Explanation/Reference:


質問 # 57
Refer to the exhibit.

A customer network uses OSPFv2 and MP-BGP protocols A network administrator installs a new Cisco Nexus Switch in the data center but experiences a BGP RIB failure Which action solves the issue?

  • A. Configure the route as a BGP backdoor
  • B. Change the administrative distance of OSPF to 220
  • C. Implement next-hop-self
  • D. Use a filter list for OSPF to filter both routes

正解:B


質問 # 58
Drag and drop the actions from the left onto the faults that they resolve on the right. Not all options are used.

正解:

解説:


質問 # 59
Refer to an exhibit. An engineer is troubleshooting an upgrade failure on a switch.
Which action resolves the issue?

  • A. Load a new system image.
  • B. Save the system image in NVRAM.
  • C. Reload the same system image.
  • D. Use the same system image as the kickstart image.

正解:A


質問 # 60
Drag and drop the actions from the left onto the faults that they resolve on the right. Not all options are used.

正解:

解説:


質問 # 61
Refer to the exhibit.

An engineer is configuring boot from iSCSI on a Cisco UCS B-Series Blade Server, but the LUN fails to mount. Which action resolves the issue?

  • A. Statically configure the target information in the Boot Policy.
  • B. Configure an MTU size of 9000 on the appliance port.
  • C. Configure a QoS policy on the vNIC.
  • D. Set a connection timeout value of 250 in the iSCSI Adapter Policy.

正解:A


質問 # 62

Refer to the exhibit. A network engineer is configuring the FCoE N_Port virtualization storage area network.
After the initial implementation, server 11 fails to connect to the disk array. Which action resolves the issue?

  • A. On N9K interface vfc11 and MDS interface vfc 1/1, change switchport mode configuration to E
  • B. On N9K interface vfc11 and MDS interface vfc 1/1, change switchport mode configuration to F
  • C. On N9K interface vfc11, change switchport mode configuration to NP
  • D. On MDS interface vfc 1/1, change switchport mode configuration to VF

正解:A


質問 # 63
A customer reports that the Chassis Management Controller fails to receive chassis information from Cisco UCS Manager. Which set of steps resolves the issue?

  • A. 1) Verify that the IOM firmware and Cisco UCS Manager are at the same software level.
    2) Verify that at least one physical cable between the IOM and fabric interconnect functions properly.
    3) Check for runtime link down status
    4) Reseat the affected IOM.
  • B. 1) Verify that the IOM firmware and Cisco UCS Manager are at different software levels
    2) Verify that at least two physical cables between the IOM and fabric interconnect function properly.
    3) Check for runtime link down status
    4) Reseat the affected IOM.
  • C. 1) Verify that the IOM firmware and Cisco UCS Manager are at the same software level.
    2) Verify that at least two physical cables between the IOM and fabric interconnect function properly.
    3) Check for runtime link down status.
    4) Reseat the affected IOM.
  • D. 1) Verify that the IOM firmware and Cisco UCS Manager are at different software levels.
    2) Verify that at least one physical cable between the IOM and fabric interconnect functions properly.
    3) Check for runtime link down status.
    4) Reseat the affected IOM.

正解:A

解説:
Explanation
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ts/guide/UCSTroubleshooting/UCSTroubleshooti


質問 # 64
Refer to the exhibit.

An engineer is performing a health check on ACI. Which statement about interface Ethernet 1/11 is true?

  • A. "out-of-service" indicates that no service graph is in use for this interface.
  • B. The interface policy is misconfigured.
  • C. "out-of-service" is the default interface status in ACI.
  • D. The interface is working correctly and fully operational, but it is not in use.

正解:B


質問 # 65
Refer to the exhibit. A network engineer fails to register a Cisco UCS B-Series server onto a Cisco Intersight device, which is deployed on premises using a virtual machine. Which action resolves the problem?

  • A. Generate a new token.
  • B. Configure a DNS server.
  • C. Deploy a new certificate with keys.
  • D. Enable HTTPS access.

正解:B


質問 # 66
Refer to the exhibit.

An engineer performs a POST operation using REST API on the Cisco Nexus switch to retrieve a managed object, but the operation fails. Which configuration resolves the issue?

  • A. https:/ 172.16.10.1/api/node/mo/uni/tn-Test1.xml? rsp-subtree=modified=config-only
  • B. icurl -k-v https:// 172.16.10.1/api/node/mo/uni/tn-Test1.xml? rsp-subtree=modified=config-only
  • C. https://172.16.10.1/api/node/mo/uni/tn-Test1.xml? rsp-subtree=full&rsp-prop-include=config-only
  • D. icurl -k -v https://172.16.10.1/api/mo/uni.xml?rsp-subtree=no<fv Tenant name="Test1" />

正解:C


質問 # 67
Refer to the exhibit.

The HSRP instance on both switches is showing as active. Which action resolves the issue?

  • A. Allow VLAN 100 between the switches.
  • B. Configure the HSRP timers to be the same.
  • C. Configure the IP address of N9K-B on the same subnet as N9K-A.
  • D. Configure preempt on only one of the switches.

正解:A


質問 # 68

Refer to the exhibit. An engineer must connect N2K-Fex-1 and N5K-Core-1 so that the traffic flow between the two devices uses load balancing. After inspecting the statistics of the interconnecting interfaces, the engineer concludes that only one link is used. Which action resolves the problem?

  • A. Configure source-destination load balancing on N5K-Core-1.
  • B. Configure each uplink to be a member of a separate LACP port channel.
  • C. Configure destination-mac load balancing on N5K-Core-1.
  • D. Configure the pinning max-link as 2.

正解:D

解説:
Section: Network


質問 # 69
Refer to the exhibit. A port channel on a Cisco Nexus 9000 Series Switch uplink experiences connectivity issues. Which configuration resolves the issue?

  • A. channel-group 100 mode on
  • B. channel-group 100 mode passive
  • C. channel-group 100 mode active
  • D. channel-group 100 force mode on

正解:C


質問 # 70
Refer to the exhibit.

Refer to the exhibit. The expected routes are not being leaked as expected from VRF RED to VRF BLUE. Which action resolves the issue?

  • A. Include the "le 32" knob under the RED_TO_BLUE_ACL prefix list.
  • B. Configure VRF BLUE under the BGP configuration.
  • C. Change the route targets under the VRFs.
  • D. Set the community to 65000:65000 under the route map.

正解:D


質問 # 71
When the engineer runs the command, this error is received:
opsengineer@wkst1:/home/auto/bash_scripts$ curl -s -b cookie_file_39422186.txt -X GET -k 192.15.132.101/api/node/class/Tenant.json {"totalCount":"1","imdata":[{"error":{"attributes":{"code":"400","text":"Request failed, (output omitted)"}}}]} Which action resolves the issue?

  • A. Modify the URI to 192.15.132.101/api/node/class/fvTenant.json
  • B. Regenerate the API token object
  • C. Change the HTTP verb to POST
  • D. Add the -c class Tenant flag to the cURL command

正解:A

解説:
Reference:
https://www.ciscolive.com/c/dam/r/ciscolive/emea/docs/2019/pdf/DEVNET-2000.pdf


質問 # 72
......


Cisco 300-615試験の準備には、実践的な体験、学習資料、練習試験の組み合わせが必要です。 Ciscoは、インストラクター主導のコース、eラーニングモジュール、自己ペースの学習ガイドなど、さまざまなトレーニングリソースを提供しています。これは、候補者が試験に合格するために必要な知識とスキルを開発するのに役立ちます。さらに、候補者は、オンラインで利用可能な練習試験やその他のリソースを利用して、試験形式と含まれる可能性のある質問の種類をよりよく理解することができます。


Cisco 300-615試験は、データセンターのオペレーションに関わる専門家、特にネットワーク管理者、ネットワークアーキテクト、システムインテグレータ、およびネットワークエンジニアの方々を対象としています。本試験は、データセンターテクノロジーに3〜5年以上携わった方を対象としており、複数選択形式で60〜70問の問題が90分以内に回答する必要があります。問題は、候補者のデータセンターオペレーション、システムパフォーマンス、ネットワークトラブルシューティングに関する知識をテストします。試験に合格するには、少なくとも70%のスコアが必要です。

 

Cisco 300-615公式認定ガイドPDF:https://www.goshiken.com/Cisco/300-615-mondaishu.html

無料CCNP Data Center 300-615公式認定ガイドPDFダウンロード:https://drive.google.com/open?id=1PU_ZzfJYEXTxZ5QQp5sy30L8aOQneA-A