質問 # 51
Click option that will allow you to select a FlexNIC function for the specified connection.

正解:

解説:


質問 # 52
After replacing a failed Compute Module, you notice the server profile Is not automatically assigned to the replaced server hardware. What can cause this issue?

  • A. Server profile affinity is configured to Device Day + server hardware.
  • B. The enclosure group has to be updated to match the original enclosure group.
  • C. The replacement server has more memory or CPUs than broken machine.
  • D. IL0 firmware of the replacement server is different than firmware in broken server.

正解:D


質問 # 53
Refer to the exhibit.

Which statement about the logical interconnect shown is true?

  • A. FC uplinks are not supported and will be converted to FCoE or RoCE uplinks.
  • B. Additional uplink ports can be added to ETH-Uplink to increase available bandwidth.
  • C. The maximum supported number of the internal networks for logical interconnect is configured.
  • D. For FC uplink sets, an additional uplink from second module should be added for redundancy.

正解:C


質問 # 54
What can De defined in a server profile for HPE Superdome Flex?

  • A. nPartition configuration.
  • B. Ethernet connections.
  • C. BMC settings.
  • D. Complex firmware baseline.

正解:A

解説:
In a server profile for HPE Superdome Flex, you can define the nPartition configuration. HPE OneView allows administrators to manage nPartitions (nPars), which are hardware-based partitions providing electrical isolation between different partitions of the Superdome Flex server. This includes defining partition boundaries, assigning resources like CPUs and memory, and configuring boot options.
* Option B: While BMC settings are important, nPartition configurations are more specific to Superdome Flex profiles.
* Option C: Firmware baselines can be applied but are not unique to Superdome Flex server profiles.
* Option D: Ethernet connections are typically defined for standard servers, but nPartitioning is a key feature for Superdome Flex.


質問 # 55
Your customer wants to update firmware for a compute node with no server Which server hardware can support this feature?

  • A. HPE Gen8 an later HPE ProLiant systems monitored in HPE OneView.
  • B. Any HPE server equipped with at least iL04.
  • C. Any server monitored or managed in HPE OneView.
  • D. HPE Gen 10 and later HPE ProLiant servers or Synergy compute nodes.

正解:D

解説:
To update firmware for a compute node without a server profile, you need to have HPE Gen10 and later HPE ProLiant servers or Synergy compute nodes. These systems support firmware updates directly through HPE OneView without requiring an assigned server profile.
Key Points:
* Firmware-Only Updates: Gen10 and newer hardware allow firmware updates using the Integrated Lights-Out (iLO) Advanced features managed by HPE OneView.
* No Server Profile Needed: This feature is particularly useful for hardware that is not yet deployed or does not have an operating system installed.


質問 # 56
Which location type can be selected when creating a remote schedule backup?

  • A. NFS
  • B. FTP
  • C. CIFS
  • D. SFTP

正解:D

解説:
When creating a remote scheduled backup in HPE OneView, the supported location type that can be selected is SFTP (Secure File Transfer Protocol). SFTP ensures secure transfer of backup files to a remote system by encrypting both commands and data, providing a secure method for backing up sensitive configuration information.


質問 # 57
Your customer wants to manage their HPE Superdome Flex using HPE OneView.
Which component must be added to HPE OneView to accomplish this task?

  • A. all nPARs created within the complex
  • B. Rack Management Controller (RMC)
  • C. Baseboard Management Controller (BMC)
  • D. only the base chassis from the complex

正解:C


質問 # 58
Which server profile template feature is available only for HPE Synergy compute nodes?

  • A. SAN storage management.
  • B. Storage connection management
  • C. Visualization of MACs and WWNs.
  • D. Firmware and drivers update options.

正解:D

解説:
The server profile template feature available only for HPE Synergy compute nodes is the Firmware and drivers update options integrated with the HPE Image Streamer. This allows for:
* Stateless Computing: Deploy both firmware and operating system images rapidly.
* Driver Management: Simultaneous management of firmware and drivers through server profiles.
Unique to HPE Synergy:
* HPE Image Streamer: Exclusive to HPE Synergy, enabling deployment of OS images along with firmware updates.
* Enhanced Server Profiles: Include the ability to define the complete software stack in the server profile template.


質問 # 59
Refer to the exhibit.

Which statement about the storage pools shown is true?

  • A. HPE OneView can be used to configure volume replication between these pools
  • B. Volumes created on the first storage pool cannot use data reduction technologies
  • C. Both storage pools are in a managed state and can be used for volume provisioning
  • D. Both storage pools have a license applied that enables management of these pools

正解:C


質問 # 60
You have created volumes using array management tools and imported the volumes to HPE OneView.
Which statement about these volumes is true?

  • A. Volumes imported to HPE OneView cannot be removed using the HPE OneView interface
  • B. Volumes imported to HPE OneView is managed just like a volume created using HPE OneView
  • C. A snapshot for imported volumes can be created only by using array management tools
  • D. Imported volumes are treated as private volumes and can be only used as boot volumes

正解:D


質問 # 61
You want to update the firmware for only two HPE Synergy Virtual Connect SE 32Gb FC Modules of a large environment. From which level must this procedure be initiated?

  • A. Logical Interconnect Group
  • B. Logical Enclosure
  • C. Server Profile
  • D. Logical Interconnect

正解:B


質問 # 62
Where is the association between an HPE OneView network and uplink port defined?

  • A. Within an Enclosure Group definition
  • B. Within an HPE OneView network definition
  • C. At the network set level
  • D. At the Logical Interconnect Group level

正解:D


質問 # 63
Your customer is using HPE OneView to manage HPE ProLian systems. In the same rack they also have two Aruba top-of-rack switches. Your customer wants to visualize the rack system and switches in HPE OneView.

  • A. Add the Aruba switches as monitored devices in HPE OneView
  • B. Add the Aruba switches as managed devices in HPE OneVlew.
  • C. Define the switches as unmanaged devices manually.
  • D. Start hardware discovery to add the Aruba switches.

正解:C

解説:
To visualize the rack system and the Aruba top-of-rack switches in HPE OneView, the customer should define the switches as unmanaged devices manually. By adding the Aruba switches as unmanaged devices, they become part of the rack layout within HPE OneView, allowing for a comprehensive visual representation of the physical infrastructure.
* Option A (Correct): Manually adding switches as unmanaged devices includes them in rack visualizations.
* Option B: HPE OneView does not automatically discover and add third-party switches via hardware discovery.
* Option C: Unless specifically supported, Aruba switches cannot be added as managed devices.
* Option D: Monitored devices require SNMP support and integration, which may not be available for these switches.


質問 # 64
Which firmware activation method is only available for a logical interconnect?

  • A. Parallel
  • B. Force installation
  • C. Manual orchestration
  • D. Orchestration

正解:C


質問 # 65
As a part of troubleshooting, you have to reinstall the same version of the firmware on an HPE Synergy Compute Module. Click the area within the Firmware section of the server profile that will allow you to install the same firmware version.

正解:

解説:


質問 # 66
Which locations are supported for HPE OneView remote scheduled backup? (Choose two.)

  • A. SCP
  • B. FTP
  • C. HTTP
  • D. HTTPS
  • E. SFTP

正解:A、E

解説:
Scheduled to be uploaded to the remote location.


質問 # 67
You ate implementing an HPE Synergy solution with multiple frames in one management ring. Image Streamer is not a part of this solution. How can an IPv4 address pool defined by the administrator be used In HPE OneView?

  • A. to provide static IP addresses for Logical Interconnects and Logical Enclosures
  • B. to provide static IP addresses for storage systems managed in HPE OneView
  • C. to provide static IP addresses to IL0 and interconnect modules if applicable
  • D. to provide static IP addresses for an operating system running on a Compute Module

正解:D