質問 # 36
Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They also plan a vSAN deployment leveraging HPE D3940 Storage Modules and SSD drives The customer requested the following components:
- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
- Two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- An appropriate number of vSAN Standard licenses for each compute node
- One HPE O3940 Storage Module with 40 SSDs - All required cables and options Which statement about this request is true?

  • A. One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM
  • B. vSphere Standard licenses should be replaced with Enterprise Plus licenses to enable vSAN
  • C. 20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drives.
  • D. vSphere licenses should be added, as vSAN licenses do not replace vSphere licenses

正解:B


質問 # 37
Click the option that will allow you to change the ESXI image used In an OS Deployment Plan.

正解:

解説:


質問 # 38
Click the area within the iLO management interface that will allow you to access workload Advisor.

正解:

解説:


質問 # 39
Which HPE Virtual Connect feature allows an administrator to suppress excessive inbound multicast broadcast and destination lookup failure (OLF) packets?

  • A. Loop protection
  • B. Storm control
  • C. Pause flood protection
  • D. LLDP tagging

正解:B


質問 # 40
You modified a logical interconnect group mat is used to configure logical interconnects in five different logical enclosures. What will be the impact of that change?

  • A. All physical interconnects from affected logical interconnects will be placed in a maintenance mode
  • B. All logical interconnects configured using this logical Interconnect group will report inconsistency
  • C. All logical interconnects configured using this logical interconnect group will be automatically updated
  • D. All physical interconnects from the affected logical interconnects must he rebooted to activate the new configuration

正解:A


質問 # 41
Which statement about manual orchestration during the firmware update is true?

  • A. It provides an ability to select and update one side of the Interconnect topology at a time
  • B. It provides the ability to install an older firmware version than currently Installed In the interconnect
  • C. It allows all the interconnect modules to be activated manually at the same time.
  • D. It is supported only for logical enclosures with at least three frames

正解:A


質問 # 42
Your customer has an HPE Synergy frame equipped with a D3940 Storage Module. Each of the compute nodes has an appropriate storage controller Installed and two 12Gb SAS switches installed in the first fabric.
The customer reports that compute nodes cannot access the storage module. What should you verify first when troubleshooting this problem?

  • A. If there is at least one ISCSI network configured that will provide access to the module.
  • B. If the D3940 module is imported in managed state that allows volume provisioning.
  • C. If the D3940 storage module is property licensed through HPE OneView interface.
  • D. If there Is a logical interconnect created based on the 12Gb SAS switches.

正解:B


質問 # 43
You plan to configure a Link Aggregation Group (LAG) for two connections within a server profile for a compute node running an ESXI system.
What is required from the VMware side to enable LAG?

  • A. vSphere Standard license
  • B. Dedicated VMKernel port
  • C. Load balancing cluster
  • D. Virtual Distributed Switch

正解:B


質問 # 44
Your customer plans to use HPE OneView for VMware vCenter Server to deploy ESXi systems. They created a server profile template that they want to use in HPE OneView.
Put the steps required to configure HPE OneView for VMware vCenter Server on the left into their correct order on the right.

正解:

解説:


質問 # 45
Your customer has an HPE Synergy platform deployed and managed using HPE OneView. The customer also has HPE Superdome Flex with RMC deployed They plan to deploy a second nPar and HPE Superdome Flex
280 They plan to manage new components using HPE OneView
What must be done to achieve this goal?

  • A. The customer must add a second Rack Management Controller for HPE Superdome Flex 280
  • B. The customer has to add HPE Superdome Flex to the HPE OneView used to manage HPE Synergy
  • C. The customer should deploy an HPE OneView appliance for HPE Superdome Flex management
  • D. The customer must use IL05 to add HPE Superdome Flex systems to HPE OneView

正解:A


質問 # 46
Which statement about HPE Superdome Flex 280 is true?

  • A. It can support up to two nPars with an external RMC.
  • B. It must be equipped with at least 768 GB of memory.
  • C. It supports 2 to 8 sockets in 2-socket increments.
  • D. it cannot be managed using HPE OneView.

正解:B


質問 # 47
An administrator tries to open iLO interlace from HPE OneView Instead of being automatically logged in a login prompt displays Where should you start the troubleshooting process?

  • A. At the iLO interface to verify whether the ILO Advanced license is properly applied
  • B. At HPE OneView Interface to verify whether the iLO processor is disabled
  • C. At HPE OneView Interface to verify whether the server is In the maintenance mode
  • D. At the iLO interface to verify whether the SSO certificate is removed from an iLO.

正解:A


質問 # 48
You need to setup HPE Synergy frames after hardware components are discovered within HPE OneView.
Put the steps to achieve this goal into the coned order in the answer area on the right.

正解:

解説:


質問 # 49
Your customer has 6 logical enclosures spanning 18 HPE Synergy frames. The customer needs to add one more logical enclosure based on 5 HPE Synergy frames How will this change impact the customer environment?

  • A. The customer can add a new logical enclosure to the existing setup because the maximum number of logical enclosures in a single management ring is not reached.
  • B. The customer can add a new logical enclosure to an existing setup once all required licenses are added lo HPE OneView and associated with the new frames.
  • C. The customer has to create a new management ring for new logical enclosure because the maximum number of frames m a single management ring is reached.
  • D. The customer has to expand the management ring capacity either by adding HPE Composer 2 modules or adding memory to reach 128GB per module.

正解:A


質問 # 50
You need to configure a RoCE network to enable lossless networking for HPE J2000 Flash Enclosure support Which interconnects are required to support this connection? (Select two.)

  • A. HPE Virtual Connect SE 16Gb FC Module for HPE Synergy
  • B. Brocade 32Gb Fibre Channel SAN Switch Module for HPE Synergy
  • C. Brocade 16Gb Fibfe Channel SAN Switch Module for HPE Synergy
  • D. HPE Virtual Connect SE 32Gb FC Module for HPE Synergy
  • E. HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy
  • F. HPE Virtual Connect SE 40Gb F8 Module for HPE Synergy

正解:A、D


質問 # 51
Which statement about HPE Apollo 2000 Gen10 Plus platform is true?

  • A. It offers servers with AMD EPYC and Intel Xeon Scalable CPUs
  • B. It can support a single processor only and up to 4 per chassis
  • C. It is fully managed using HPE OneView including all connections
  • D. It is equipped with HPE Persistent memory by default

正解:B


質問 # 52
Your customer wants to add dedicated Fibre Channel connectivity to the HPE Synergy frame running HPE Synergy 480 Gen10 compute modules, each with one CPU socket populated Currently they use two 12 Gb SAS switches and two HPE Virtual Connect SE 100Gb F32 Modules for HPE Synergy installed in third fabric.
What must be done to enable dedicated FC connectivity for this HPE Synergy frame?

  • A. For VC-FC modules, all of server facing ports must be property licensed.
  • B. SAS switches must be moved to second fabric and FC modules Installed in the first one.
  • C. For Brocade switches, a logical interconnect group must be created in HPE OneView.
  • D. A second CPU must be installed for all HPE Synergy 480 Gen10 compute nodes.

正解:B


質問 # 53
After deploying HPE Superdome Flex 280 you need to check Core Analysis Engine (CAE) Log.
Click the appropriate section in the HPE Superdome Flex 280 management interface that will allow you to complete this task.

正解:

解説:


質問 # 54
Your customer wants to add a second HPE Synergy frame to an existing logical enclosure Based on a single HPE Synergy frame. The customer wants to use a highly available master setup.
Which procedures should De performed during the expansion process? (Select two.)

  • A. Create a new logical enclosure based on both HPE Synergy frames.
  • B. Create a new logical interconnect group and enclosure group for two frames setup
  • C. Modify an existing logical interconnect to include second HPE Synergy frame.
  • D. Move one of the master modules to the appropriate interconnect bay in the second frame.
  • E. Re-parent an existing enclosure group to the new logical interconnect group.

正解:A、C


質問 # 55
Your customer plans to deploy ESXi systems to HPE Synergy and HPE ProLiant servers using HPE OneView for VMware vCenter Server.
Which statement about HPE OneView for VMware vCenter Server functionality is true for this environment?

  • A. HPE ProLiant servers need an HPE OneView for VMware vCenter Server license for full functionality
  • B. HPE Synergy requires HPE Composer 2 for full functionality of HPE OneView for VMware vCenter Server
  • C. Individual systems can be added to HPE OneView for VMware vCenter Server through an ILO management processor
  • D. Only systems managed using HPE Oneview can use HPE Oneview for VMware vCenter Server functionalities

正解:A


質問 # 56
Refer to the exhibit.

Which statement about this logical interconnect group is true?

  • A. Both master modules are located in the same HPE S ynergy frame
  • B. For the given downlink speed, the maximum number of frames is reached
  • C. The master modules are located in the interconnect bays 2 and 5
  • D. To use interconnect bay set 3, all compute nodes must be half-height

正解:A


質問 # 57
Which statement about the SY480 Gen10 Plus Compute Module is true?

  • A. It cannot be mixed with Gen9 compute modules in the same frame.
  • B. It only supports NVDIMM Persistent Memory.
  • C. It supports 8 memory channels and memory DIMMs of up to 256GB.
  • D. It supports "3rd Gen AMO EPYC Server Processors with 64 cores.

正解:B