NFPA CFPS 認定試験の出題範囲:

トピック出題範囲
トピック 1
  • Facility Fire Hazard Management: The exam will assess the proficiency of Fire protection consultants in managing and mitigating fire hazards in facilities through effective planning and system management. Candidates must demonstrate their understanding of architectural drawings, risk assessments, and the integration of fire protection systems to ensure safety across all building operations and emergency preparedness protocols.
トピック 2
  • Fire Prevention: Programs, Materials, Processes, and Environments: This topic assesses capability in identifying fire hazards and applying mitigation strategies to minimize risks in a community or organization. Fire protection consultants will be tested on their ability to conduct safety audits, provide fire hazard training, and recommend safety tools and equipment.
トピック 3
  • Safety in the Built Environment: This topic will test the knowledge and skills of Fire protection consultants in evaluating and ensuring the proper application of fire protection systems in various buildings. They must demonstrate their ability to analyze fire safety protocols, building systems, and regulations for compliance.
トピック 4
  • Information and Analysis for Fire Protection and Fire Science: In this section, Fire protection consultants will be evaluated on their ability to conduct fire loss investigations, fire analysis, and protection calculations. Their ability to assess fire dynamics and the impacts on building occupants is crucial for ensuring proper safety measures are in place.

 

質問 # 12
Requirements for the installation, operation, and maintenance of electrical emergency system circuits and equipment are given in the National Electrical Code (NEC).

  • A. Article 500
  • B. Article 800
  • C. Article 700
  • D. Article 600

正解:A

解説:


質問 # 13
Components in an exhaust system for commercial cooking installation include the ductwork, the exhaust fan, and the:

  • A. grease filtration devices
  • B. gas supply valve
  • C. air intake valve
  • D. cooking appliances

正解:B

解説:
Provisions cover the design; installation; operation; and inspection, testing, and maintenance of the full spectrum of cooking equipment, hoods, grease removal devices, exhaust duct systems, fans, fire suppression systems, and clearance to combustibles.


質問 # 14
What type of property classifications experience the majority of fire deaths in the United States?

  • A. One- and two-family dwellings
  • B. Educational
  • C. Public Assembly
  • D. Business

正解:A

解説:
Explanation
The type of property classifications that experience the majority of fire deaths in the United States areone- and two-family dwellings.According to the NFPA, one- and two-family dwellings accounted for 64 percent of all civilian fire deaths in 2021, followed by apartments with 11 percent, and other residential properties with 1 percent1.One- and two-family dwellings are more vulnerable to fire fatalities because they often lack adequate fire protection systems, such as smoke alarms and sprinklers, and havemore potential sources of ignition, such as cooking, heating, and smoking2. Additionally, one- and two-family dwellings may have less escape routes, longer response times, and more occupants, especially children and elderly, who are at higher risk of fire death.References:
US Fire Loss in 2021 NFPA
Home Structure Fires - NFPA
[Fire Death Rate Trends: An International Perspective]


質問 # 15
Which type of fire alarm system transmits signals that are permanently recorded at a constantly attended supervising station located either at the protected premises or at another location of the property owner?

  • A. Proprietary
  • B. Auxiliary
  • C. Remote station
  • D. Central station

正解:A

解説:
Explanation
A proprietary fire alarm system is a type of fire alarm system that transmits signals that are permanently recorded at a constantly attended supervising station located either at the protected premises or at another location of the property owner. A proprietary fire alarm system is owned and operated by the property owner or the owner's agent. A proprietary fire alarm system is intended to provide fire alarm service to a single property or a campus of related properties.References:
NFPA 72: National Fire Alarm and Signaling Code, 2019 Edition, Section 3.3.105.11 Fire Protection Handbook, 20th Edition, Volume 1, Chapter 7, Section 7.2.1.12


質問 # 16
Which of the following would NOT be an appropriate purpose for employing a guard service to protect a property against fire loss?

  • A. To carry out procedures for the orderly conduct of some operations on the property
  • B. To protect the property at times when the management is not present
  • C. To perform routine housekeeping and equipment maintenance operations during nonproduction hours
  • D. To facilitate and control the movement of persons into, out of, and within the property

正解:C

解説:
Explanation
The correct answer is C. To perform routine housekeeping and equipment maintenance operations during nonproduction hours would NOT be an appropriate purpose for employing a guard service to protect a property against fire loss. A guard service is typically hired to provide security and protection for a property, not to perform other tasks that are unrelated to fire prevention or control. Housekeeping and equipment maintenance operations should be done by qualified and authorized personnel who are trained and equipped to handle any potential fire hazards. A guard service may not have the necessary skills, tools, or authority to perform these operations safely and effectively.Moreover, these operations may interfere with the guard service's primary duty of monitoring and patrolling the property for any signs of fire or intrusion12345


質問 # 17
For either a grain dust fire or explosion to occur and be sustained, which of the following elements must be present?

  • A. Fuel, ignition source, oxygen, and combustible dust
  • B. Fuel, oxygen, confinement, and ignition source
  • C. Fuel, ignition source, and oxygen
  • D. Dust, heat, and ignition source

正解:A

解説:
A dust explosion is the rapid combustion of fine particles suspended in the air, often but not always in an enclosed location. Dust explosions can occur where any dispersed powdered combustible material is present in high enough concentrations in the atmosphere or other oxidizing gaseous medium such as oxygen.
Dust explosions are a frequent hazard in underground coal mines, in grain elevators, and other industrial environments. On the other hand, they are also commonly used by special effects artists, filmmakers, and pyro technicians, given their spectacular appearance and ability to be safely contained under certain carefully controlled conditions.
Conditions required
There are four necessary conditions for a dust explosion
* A combustible dust
* The dust is suspended in the air at a sufficiently high concentration
* There is an oxidant (typically atmospheric oxygen)
* There is an ignition source
In some traditional analyses of dust explosions, confinement is considered to be a fifth requirement; this is not an essential condition, but can greatly aggravate the physical damage that results.
How do combustible dust explosions happen?
Any fire needs three elements. These elements are known as the "fire triangle":
1. Fuel to burn
2. Oxygen
3. Ignition source (heat, spark, etc.)
A dust explosion needs two additional elements - known as the "dust pentagon":
4. Dispersion of dust particles in the right concentration, and
5. Confinement of the dust cloud.
Dispersion means the dust particles are suspended in air. Confinement means the dust is in an enclosed or limited space. This restriction allows pressure to build up, increasing the likelihood of an explosion.

Figure shows the dust explosion pentagon. Figure from Occupational Safety and Health Administration (OSHA).


質問 # 18
Which of the following is the correct UL classification of roof covering that include criteria for resistance to ignition?

  • A. Option B
  • B. Option D
  • C. Option A
  • D. Option C

正解:D


質問 # 19
What are the human health effects of exposure for two minutes at a concentration of less than 50 ppm of hydrogen fluoride?

  • A. Slight eye and nasal irritation.
  • B. Mild eye and upper respiratory tract irritation.
  • C. Moderate eye and upper respiratory tract irritation.
  • D. Moderate irritation of all body surfaces.

正解:B

解説:
Explanation
According to the CDC, exposure to hydrogen fluoride at concentrations of less than 50 ppm for two minutes may cause mild eye and upper respiratory tract irritation. The severity of the effects depends on the concentration, duration, and route of exposure, as well as the individual's susceptibility. Higher concentrations or longer exposures can cause more serious health effects, such as pulmonary edema, skin burns, or systemic toxicity.References:CDC | Facts About Hydrogen Fluoride (Hydrofluoric Acid); [Hydrogen Fluoride (HF) | Medical Management Guidelines | Toxic Substance Portal | ATSDR]2; [Hydrogen Fluoride and Hydrofluoric Acid (HF) - GOV.UK]3.


質問 # 20
What is the minimum width requirement for a window used as a second means of egress from a one- or two-family dwelling?

  • A. 32.4 inches (823 mm)
  • B. 34.2 inches (869 mm)
  • C. 24 inches (610mm)
  • D. 20 inches (510 mm)

正解:B

解説:
It shall be an outside window or door operable from the inside without the use of tools, keys, or special effort and shall provide a clear opening of not less than 5.7 ft2 (0.53 m2). The width shall be not less than 20 in. (510 mm), and the height shall be not less than 24 in. (610 mm). The bottom of the opening shall be not more than 44 in. (1120 mm) above the floor. Such means of escape shall be acceptable where one of the following criteria is met:
(1) The window shall be within 20 ft (6100 mm) of the finished ground level.
(2) The window shall be directly accessible to fire department rescue apparatus as approved by the authority having jurisdiction.
(3) The window or door shall open onto an exterior balcony.
(4) Windows having a sill height below the adjacent finished ground level shall be provided with a window good meeting all of the following criteria:
(a) The window well shall have horizontal dimensions that allow the window to be fully opened.
(b) The window well shall have an accessible net clear opening of not less than 9 ft2 (0.82 m2) with a length and width of not less than 36 in. (915 mm).
(c) A window well with a vertical depth of more than 44 in. (1120 mm) shall be equipped with an approved permanently affixed ladder or with steps meeting both of the following criteria:
I) The ladder or steps shall not encroach more than 6 in. (150 mm) into the required dimensions of the window well.
iI) The ladder or steps shall not be obstructed by the window.


質問 # 21
An agent that takes weeks to evaporate is said to be:

  • A. persistent.
  • B. volatile.
  • C. hydrogenated.
  • D. stable.

正解:D


質問 # 22
In what year between 1980 and 2002, did the worst civilian injuries in industrial and manufacturing property structural fires occur?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解:A

解説:


質問 # 23
What class designation is given to a standpipe system consisting of a 2 . inch (6.35 cm) hose valve specifically for fire department use and a 1 . inch (3.81 cm) hose valve complete with hose and nozzles for building occupant use?

  • A. Class I
  • B. Class II
  • C. Class IV
  • D. Class III

正解:C


質問 # 24
Pressure readings at the inlet flange of a pump operating under lift are:

  • A. negative with respect to the gauge and positive when referred to absolute pressure
  • B. positive with respect to the gauge and negative when referred to absolute pressure
  • C. equal with respect to the gauge and negative when referred to absolute pressure
  • D. negligible with respect to the gauge and equal when referred to absolute pressure

正解:B


質問 # 25
Which of the following is least important when considering the test plan for the inspection, testing, and maintenance regimen for a fire alarm system?

  • A. How it is to be performed
  • B. How frequently the specific procedure is to be performed
  • C. What procedure is to be performed
  • D. Who is to be notified of the procedure

正解:C


質問 # 26
What is the background color used from the source to the outlets of a nitrous oxide medical gas system?

  • A. Blue
  • B. Yellow
  • C. Black
  • D. Gray/black

正解:A

解説:
Explanation
The background color used from the source to the outlets of a nitrous oxide medical gas system is blue. This is the standard color coding for nitrous oxide cylinders and pipelines in medical gas pipeline systems12. The color coding helps to identify the gas type and prevent accidental misconnections or cross-contamination3. The color coding also indicates the pressure and flow characteristics of the gas system4. References:
Colour coding of copper pipes in Medical gas pipeline system according ...
Doc 177 20 Medical Gas Cylinders Colour Coding - EIGA
Medical Gas Coding Color Chart & Explanation - Bay Corporation
Medical gases Health Technical Memorandum 02-01: Medical gas pipeline ...


質問 # 27
In a hotel that has up to and including four stories, the sprinkler system may be installed according to:

  • A. NFPA 13D
  • B. NFPA 13R
  • C. NFPA 13E
  • D. NFPA 13

正解:B


質問 # 28
The primary design approach to mitigate the effect of wind on smoke movement in high-rise buildings is based on

  • A. fire department access.
  • B. tightness of the building.
  • C. outside temperature.
  • D. height of the building.

正解:B


質問 # 29
Combustibles should be moved away from cutting and welding operations a minimum distance of ________.

  • A. 35 ft (10.6 m)
  • B. 30 ft (9.1 m)
  • C. 45 ft (13.7 m)
  • D. 40 ft (12.2 m)

正解:A

解説:
1910.252(a)(2)(iii)(A)(1)
Appreciable combustible material, in building construction or contents, closer than 35 feet (10.7 m) to the point of operation.
1910.252(a)(2)(iii)(A)(2)
Appreciable combustibles are more than 35 feet (10.7 m) away but are easily ignited by sparks.
1910.252(a)(2)(iii)(A)(3)
Wall or floor openings within a 35-foot (10.7 m) radius expose combustible material in adjacent areas including concealed spaces in walls or floors.


質問 # 30
When storing Class IB flammable liquids outdoors in portable containers, what is the maximum quantity and height allowed for composite Intermediate Bulk Containers (IBCs) per pile?

  • A. 22,000 gallons and 18 ft
  • B. Not permitted for composite IBCs
  • C. 4,400 gallons and 14 ft
  • D. 8,800 gallons and 12 ft

正解:A


質問 # 31
The duration of required fire flow in public supply systems ranges from

  • A. 1-4 hours.
  • B. 1-6 hours.
  • C. 3-8 hours.
  • D. 2-10 hours.

正解:A


質問 # 32
......