質問 # 180
For which VxRail models must the iDRAC NIC Selection be set to Dedicated?

  • A. D, E, P, S, and V Series
  • B. E, P, S, and V Series only
  • C. D, G, P, S, and V Series
  • D. D, E, and G Series

正解:A


質問 # 181
When validating the completed VxRail PEQ, you note the following VLANs in the configuration:\
- VxRailManagement - VLAN 120
- vSAN - VLAN 121
- vMotion - VLAN 122
- Servers - VLAN 204
- NetManagement - VLAN 208
Which command should you use to validate that the VLANs are configured on each Dell EMC ToR switch?

  • A. show vlan
  • B. show interfaces status
  • C. show running-config spanning-tree
  • D. show interfaces port-channel brief

正解:A


質問 # 182
A 4-node VxRail Model E560F solution with an embedded vCenter and Log Insight is planned for deployment.
Prior to deployment, DNS records must be created for which hosts?

  • A. vCenter Server, ESXi hosts, VxRail Manager, and iDRAC
  • B. vCenter Server, first ESXi host, VxRail Manager, and iDRAC
  • C. vCenter Server, ESXi hosts, VxRail Manager, and Log Insight
  • D. DNS records are automatically created during VxRail deployment

正解:C


質問 # 183
A company is planning to deploy VxRail for business critical applications. The solution should support automated workload re-balancing.
Which vSphere license is required for this solution?

  • A. vSphere Enterprise Plus
  • B. vSphere Standard
  • C. vSphere Enterprise
  • D. vSphere with Operations Management Enterprise

正解:A


質問 # 184
You are asked to cable up a VxRail G Series cluster to a redundant pair of 1/10G switches.
What is the cabling best practice for this configuration?

  • A. Cable ports 1 and 2 to one switch. Cable ports 3 and 4 to the other switch. Cable BMC from node 1 and 2 to one switch. Cable BMC from node 3 and 4 to the other switch.
  • B. Cable ports 1 and 3 to one switch. Cable ports 2 and 4 to the other switch. Cable BMC from node 1 and 3 to one switch. Cable BMC from node 2 and 4 to the
  • C. Cable ports 1 and 2 to one switch. Cable ports 3 and 4 to the other switch.
  • D. Cable ports 1 and 3 to one switch. Cable ports 2 and 4 to the other switch.

正解:B


質問 # 185
What step is a best practice in the deployment process of a VxRail Appliance with an External vCenter server?

  • A. Create VxRail Management user in SSO with administrative privileges
  • B. Connect to DCUI to set vLAN tagging on ESXi hosts
  • C. Create VxRail Configuration user in SSO with no role assigned
  • D. SSH to the default IP address of the VxRail Manager VM to set the required IP address

正解:D


質問 # 186
What output logs are collected using the vc-support.sh script?

  • A. vRealize Log Insight support bundle
  • B. VxRail Manager log bundle
  • C. ESXi log bundle
  • D. vCenter log bundle

正解:C


質問 # 187
What is the correct CLI command to collect only the iDRAC logs for node HL2S8N2?

  • A. vm-support.sh --nodes HL2S8N2 -i
  • B. vc-support-bundle.sh --nodes HL2S8N2 -i
  • C. generateLogBundle.py --nodes HL2S8N2 -i
  • D. generateFullBundle.py --nodes HL2S8N2 -i

正解:C


質問 # 188
When populating the VxRail Installation wizard for an External vCenter solution, what is the correct format for hostnames?

  • A. vCenter, PSC, and VxRail Manager should use host name only
  • B. vCenter, PSC, and VxRail Manager should use FQDN
  • C. VxRail Manager and vCenter should use FQDN; PSC should use host name only
  • D. vCenter and PSC should use FQDN; VxRail Manager should use host name only

正解:A


質問 # 189
Which vSAN feature requires an All-Flash cluster?

  • A. Deduplication and compression
  • B. Data-at-Rest Encryption
  • C. Storage Policy Based Management
  • D. Data-in-Transit Encryption

正解:A


質問 # 190
An implementation engineer is in the validation phase of a VxRail deployment with two Dell EMC ToR switches.
Which command should they run on each of the ToR switches to validate that Link Aggregation has been configured according to Dell best practices for VxRail node interfaces?

  • A. show interface status
  • B. show port-channel summary
  • C. show interface
  • D. show network-policy profile

正解:B


質問 # 191
What is the minimum number of VxRail nodes required for a vSAN storage policy with FTT = 2 an6 FTM set to Erasure Coding?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解:D


質問 # 192
An implementation engineer is tasked with setting up RecoverPoint for VMs on a 5-node V570F cluster.
How many VMs are licensed to be protected on the cluster?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解:B


質問 # 193
To investigate a problem on a VxRail system, the onsite engineer has to collect the complete set of logs.
Which method will collect all logs at once?

  • A. Run /mystic/generateFullLogBundle command in VxRail Manager CLI
  • B. Download https://:443/appliance /support-bundle
  • C. Click "Generate New Log Bundle" in the VxRail Manager GUI
  • D. Export vCenter system logs

正解:D


質問 # 194
During the installation of a new VxRail cluster, where is System Time configured?

  • A. iDRAC Settings > System Time
  • B. System BIOS > Miscellaneous Settings
  • C. iDRAC Settings > System Profile Settings
  • D. System BIOS > System Information

正解:B


質問 # 195
A customer is configuring VxRail to connect to an existing, external SRS VE. Their support account is associated with the Site ID/Party ID where VxRail is installed. A validation error is issued when the customer attempts to register VxRail in SRS.
What is the possible cause for the error?

  • A. Wrong IP address was used for SRS VE gateway
  • B. Status of VxRail in Install Base is 'Shipped'
  • C. Number of deployed devices on SRS gateway has exceeded the maximum
  • D. SRS traffic goes through a proxy server

正解:B


質問 # 196
How does an implementer get a local VxRail Configuration XML file so they can generate an As-Built Configuration Report?

  • A. Log in to vCenter with the vSphere Client with the vCenter Server Management user
    Go to Monitor > VxRail > Last Configuration Data Sent
    Use the Download option
  • B. Open an FTP connection to the VxRail Manager VM with the mystic user
    Go to the /var/lib/vmware-marvin directory
    GET the config-initial.json file
  • C. Log in to vCenter with the vSphere Client with the vCenter Administration user
    Go to Configure > VxRail > System
    Use the Product Documentation option
  • D. SSH to the VxRail Manager VM with the mystic user
    SU to root
    Go to the /opt/VxRail/config directory
    SCP the initial-config.json file to a local location

正解:A